{"id":6897,"date":"2020-06-24T10:27:00","date_gmt":"2020-06-24T10:27:00","guid":{"rendered":"https:\/\/teguar.com\/eu\/?p=6897"},"modified":"2025-10-29T15:18:14","modified_gmt":"2025-10-29T15:18:14","slug":"clean-room-computer-hardware","status":"publish","type":"post","link":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/","title":{"rendered":"Clean Room Requirements for Computer Hardware"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/teguar.com\/eu\/wp-content\/uploads\/sites\/2\/2020\/08\/clean_room_manufacturing.jpg\" alt=\"Engineer wearing protective clothing uses manufacturing equipment in a clean room\" class=\"wp-image-6894\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-what-is-a-clean-room\">What is a Clean Room?<\/h3>\n\n\n\n<p>A clean room is an environment where airborne contaminants (dust, microbes, and particles) are highly controlled. The number of particles in the air and the size of particles in the air are kept below specific thresholds, and those thresholds depend on the class of the clean room.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-applications-for-clean-rooms\">Applications for Clean Rooms<\/h3>\n\n\n\n<p>Clean rooms are used for applications such as food manufacturing, pharmaceutical production, aerospace engineering, and biomedical research, because even a microscopic contaminant can adversely affect these processes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-classes-of-clean-rooms\">Classes of Clean Rooms<\/h3>\n\n\n\n<p>Classes of clean rooms are set by the International Organization for Standardization (ISO). ISO sets standards for many industries, including food and drug manufacturing, and computer hardware manufacturing (<a href=\"https:\/\/teguar.com\/eu\/iso-9001-certified-computer-company\" target=\"_blank\" rel=\"noreferrer noopener\">Teguar is ISO 9001:2015<\/a>&nbsp;certified).<\/p>\n\n\n\n<p>The ISO clean room classes set the threshold for the number of particles in the air, per cubic meter (particles\/m<sup>3<\/sup>). The limits are different for different sized particles. The particles range from 0.1 \u03bcm to 5 \u03bcm in diameter (\u03bcm is a micrometer, also called a micron. It is equal to 0.001 mm, or about 0.000039 inch. As defined by&nbsp;<a href=\"https:\/\/www.britannica.com\/science\/micrometre\" target=\"_blank\" rel=\"noreferrer noopener\">Britannica<\/a>).<\/p>\n\n\n\n<p>To put that number in perspective, the human eye cannot see anything smaller than about 40 \u03bcm. Human hair is about 50-100 \u03bcm in diameter and bacteria are about 2 \u03bcm in diameter. See the table below from&nbsp;<a href=\"http:\/\/www.hastingsfilter.com\/Literature\/TechTips\/TechTips2014-03.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Hastings Filters<\/a>, to see some other comparisons.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/teguar.com\/eu\/wp-content\/uploads\/sites\/2\/2020\/08\/what-is-a-micron.png\" alt=\"Diagram showing the relative sizes of small objects in microns\" class=\"wp-image-6895\"\/><\/figure>\n\n\n\n<p>The classes range from class 1, being the cleanest and most highly filtered, to class 9, which is the typical ambient air around us every day. The&nbsp;<a href=\"https:\/\/www.cmmonline.com\/articles\/infographic-basic-cleanroom-requirements-and-classifications\" target=\"_blank\" rel=\"noreferrer noopener\">table below by Cleaning Maintenance Management<\/a>&nbsp;displays the concentration limits per particle size, for each class.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/teguar.com\/eu\/wp-content\/uploads\/sites\/2\/2020\/08\/ISO-classes-for-cleanrooms.png\" alt=\"Chart showing ISO classes of air cleanliness by particle concentration\" class=\"wp-image-6896\"\/><\/figure>\n\n\n\n<p>Up until 2001, standards for clean room environments were set by the Federal Standard 209E (FED-STD-209). You may still see some clean room manufacturers use the term \u201cclass 10,000 clean room\u201d to refer to an ISO Class 7 clean room.&nbsp;<a href=\"https:\/\/www.iest.org\/Standards-RPs\/ISO-Standards\/FED-STD-209E\" target=\"_blank\" rel=\"noreferrer noopener\">FED-STD-209 was officially replaced by ISO standards<\/a>&nbsp;in 2001. The table below shows the FED-STD-209 equivalent to the new ISO classifications.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>ISO 14644-1 &nbsp; &nbsp;&nbsp;<\/td><td>FED-STD-209E &nbsp; &nbsp;&nbsp;<\/td><\/tr><tr><td>Class 1<\/td><td>N\/A<\/td><\/tr><tr><td>Class 2<\/td><td>N\/A<\/td><\/tr><tr><td>Class 3<\/td><td>Class 1<\/td><\/tr><tr><td>Class 4<\/td><td>Class 10<\/td><\/tr><tr><td>Class 5<\/td><td>Class 100<\/td><\/tr><tr><td>Class 6<\/td><td>Class 1,000<\/td><\/tr><tr><td>Class 7<\/td><td>Class 10,000<\/td><\/tr><tr><td>Class 8<\/td><td>Class 100,000<\/td><\/tr><tr><td>Class 9<\/td><td>N\/A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-how-to-maintain-a-clean-room-environment\">How to Maintain a Clean Room Environment?<\/h3>\n\n\n\n<p>Clean rooms are maintained by highly specialized ventilation systems. Unlike ventilation in a normal environment, in a clean room, the air flow is unidirectional. This means there cannot be any fans (such as those inside a typical computer), which push air around, as this will interfere with the unidirectional movement of the clean room ventilation system. Clean rooms use either High-Efficiency Particulate Air (HEPA) or Ultra-Low Particulate Air (ULPA) filters in their ventilation system.<\/p>\n\n\n\n<p>The clothing that clean room personnel wear is also highly regulated. According to&nbsp;<a href=\"https:\/\/www.cleanairtechnology.com\/cleanroom-classifications-class.php\" target=\"_blank\" rel=\"noreferrer noopener\">Clean Air Technology, Inc.<\/a>, required \u201ccleanroom garments [can] include boots, shoes, aprons, beard covers, bouffant caps, coveralls, face masks, frocks\/lab coats, gowns, glove and finger cots, hairnets, hoods, sleeves and shoe covers.<\/p>\n\n\n\n<p>Depending on the class of the clean room, personnel may be required to enter an \u201cair shower\u201d before entering the cleanroom. This is a separate room that blows dust and particles off of the person, before he or she enters the clean room environment. Personnel cannot wear makeup or perfumes and are required to cover their hair.&nbsp;<a href=\"https:\/\/blog.gotopac.com\/2018\/02\/14\/cleanroom-preparation-procedure\/\" target=\"_blank\" rel=\"noreferrer noopener\">This article from Production Automation Corporation<\/a>&nbsp;describes a typical process that clean room personnel undergo before entering a clean room; it\u2019s a 43 step process.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-computer-hardware-requirements-for-clean-room-manufacturing\">Computer Hardware Requirements for Clean Room Manufacturing<\/h3>\n\n\n\n<p>For food and beverage manufacturing and some pharmaceutical production environments, computers must be able to withstand daily wash-downs. Equipment is sanitized with high-pressure, high-temperature water jets. Computers in these environments are made with grade SUS304 stainless steel, which is rust-proof and anti-corrosion. Some environments require a higher grade SUS316L stainless steel, which will not corrode, even to salt water. These computers are fully sealed and rated IP69K waterproof, so they will not allow any liquid to enter the computer, even with water jets spraying from all angles.<\/p>\n\n\n\n<p>In applications such as biomedical research and aerospace engineering, equipment is not usually sprayed with water jets, but is wiped down frequently with disinfectants. In this case, the computer needs to be able to withstand strong chemical disinfectants, which consumer-grade computers cannot. Computers in these applications can be built with stainless steel or medical-grade plastic. Medical-grade plastic will not corrode or degrade from the frequent use of disinfectants, and it is built with antimicrobial properties. Learn more antimicrobial and medical-grade computer housings in&nbsp;<a href=\"https:\/\/teguar.com\/eu\/blog\/antimicrobial-coating-medical-grade-plastic\/\" target=\"_blank\" rel=\"noreferrer noopener\">this Teguar article<\/a>. &nbsp;<\/p>\n\n\n\n<p>Whether the computer is made with antimicrobial plastic or stainless steel, it must have a fanless cooling system. Clean room computers should also be designed with minimal crevices, where dust and particles build up. Full-flat front bezels minimize crevices and edges and are easier to spray and clean.<\/p>\n\n\n\n<p>Many clean room manufacturers choose Teguar\u2019s all-in-one, waterproof touchscreen computers, because they can be customized to their application and can integrate peripherals like speakers and barcode scanners. This is beneficial for clean rooms, because peripherals take up space and add time to the cleaning process. The touchscreen also eliminates the need for an external keyboard and mouse.<\/p>\n\n\n\n<p>To learn more about cleanroom computers, view&nbsp;<a href=\"https:\/\/teguar.com\/eu\/applications\/clean-room-computer.html\" target=\"_blank\" rel=\"noreferrer noopener\">Teguar\u2019s Clean Room Application Page<\/a>, our&nbsp;<a href=\"https:\/\/teguar.com\/eu\/waterproof-computer.html\" target=\"_blank\" rel=\"noreferrer noopener\">Stainless Steel Computers<\/a>,&nbsp;<a href=\"https:\/\/teguar.com\/eu\/medical-computers.html\" target=\"_blank\" rel=\"noreferrer noopener\">Medical Computers<\/a>, or&nbsp;<a href=\"https:\/\/teguar.com\/eu\/contactus\">contact us<\/a>&nbsp;to discuss your project.<\/p>\n\n\n<div class=\"hs-cta-embed hs-cta-embed-167100924447\" style=\"max-width:100%; max-height:100%; width:1410px;height:318.8999938964844px\" data-hubspot-wrapper-cta-id=\"167100924447\">\n  <link rel=\"stylesheet\" href=\"https:\/\/js.hscta.com\/embeddable_cta_placeholder_v1.css\">\n<div class=\"hs-cta-loading-dot__container\">\n<div class=\"hs-cta-loading-dot\"><\/div>\n<div class=\"hs-cta-loading-dot\"><\/div>\n<div class=\"hs-cta-loading-dot\"><\/div>\n<\/p><\/div>\n<div class=\"hs-cta-embed__skeleton\"><\/div>\n<picture><source srcset=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" media=\"(max-width: 480px)\" \/><img decoding=\"async\" alt=\"Let's talk about your project. &nbsp; Enter your name and a convenient contact email address and a Teguar account manager will reach out to you within one business day to get your project started.\" loading=\"lazy\" src=\"https:\/\/no-cache.hubspot.com\/cta\/default\/21497995\/interactive-167100924447.png\" style=\"height: 100%; width: 100%; object-fit: fill\" onerror=\"this.style.display='none'\" \/>\n  <\/picture>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What is a Clean Room? A clean room is an environment where airborne contaminants (dust, microbes, and particles) are highly controlled. The number of particles in the air and the size of particles in the air are kept below specific thresholds, and those thresholds depend on the class of the clean room. Applications for Clean [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":6894,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2283],"tags":[2306,2338,2339,2321],"class_list":["post-6897","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-articles-industry-trends","tag-antimicrobial-computer","tag-clean-room","tag-cleanroom","tag-stainless-steel-computer"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Clean Room Requirements for Computer Hardware | Teguar<\/title>\n<meta name=\"description\" content=\"What is a cleanroom, how are clean rooms monitored, and what type of computers can be used for clean room manufacturing?\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Clean Room Requirements for Computer Hardware\" \/>\n<meta property=\"og:description\" content=\"What is a cleanroom, how are clean rooms monitored, and what type of computers can be used for clean room manufacturing?\" \/>\n<meta property=\"og:url\" content=\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\" \/>\n<meta property=\"og:site_name\" content=\"Teguar\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-24T10:27:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-29T15:18:14+00:00\" \/>\n<meta name=\"author\" content=\"Kathryn Armstrong\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kathryn Armstrong\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\"},\"author\":{\"name\":\"Kathryn Armstrong\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/#\/schema\/person\/be5b4ccaf92e94f4a0336b6c8c7bf779\"},\"headline\":\"Clean Room Requirements for Computer Hardware\",\"datePublished\":\"2020-06-24T10:27:00+00:00\",\"dateModified\":\"2025-10-29T15:18:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\"},\"wordCount\":895,\"image\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage\"},\"thumbnailUrl\":\"\",\"keywords\":[\"Antimicrobial Computer\",\"clean room\",\"cleanroom\",\"stainless steel computer\"],\"articleSection\":[\"Technical Articles &amp; Industry Trends\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\",\"url\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\",\"name\":\"Clean Room Requirements for Computer Hardware | Teguar\",\"isPartOf\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2020-06-24T10:27:00+00:00\",\"dateModified\":\"2025-10-29T15:18:14+00:00\",\"author\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/#\/schema\/person\/be5b4ccaf92e94f4a0336b6c8c7bf779\"},\"description\":\"What is a cleanroom, how are clean rooms monitored, and what type of computers can be used for clean room manufacturing?\",\"breadcrumb\":{\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/teguar.com\/eu\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Clean Room Requirements for Computer Hardware\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/#website\",\"url\":\"https:\/\/teguar.com\/eu\/en\/\",\"name\":\"Teguar\",\"description\":\"Industrial PCs, Medical Computers, and Rugged Tablets\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/teguar.com\/eu\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/teguar.com\/eu\/en\/#\/schema\/person\/be5b4ccaf92e94f4a0336b6c8c7bf779\",\"name\":\"Kathryn Armstrong\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/c83b2b0424b6b6216f32b7790cb38c76d9ba87ccb83d2ff1f9fc00f916b0334c?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c83b2b0424b6b6216f32b7790cb38c76d9ba87ccb83d2ff1f9fc00f916b0334c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c83b2b0424b6b6216f32b7790cb38c76d9ba87ccb83d2ff1f9fc00f916b0334c?s=96&d=mm&r=g\",\"caption\":\"Kathryn Armstrong\"},\"url\":\"https:\/\/teguar.com\/eu\/en\/author\/kathryn-armstrong\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Clean Room Requirements for Computer Hardware | Teguar","description":"What is a cleanroom, how are clean rooms monitored, and what type of computers can be used for clean room manufacturing?","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/","og_locale":"en_US","og_type":"article","og_title":"Clean Room Requirements for Computer Hardware","og_description":"What is a cleanroom, how are clean rooms monitored, and what type of computers can be used for clean room manufacturing?","og_url":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/","og_site_name":"Teguar","article_published_time":"2020-06-24T10:27:00+00:00","article_modified_time":"2025-10-29T15:18:14+00:00","author":"Kathryn Armstrong","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kathryn Armstrong","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#article","isPartOf":{"@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/"},"author":{"name":"Kathryn Armstrong","@id":"https:\/\/teguar.com\/eu\/en\/#\/schema\/person\/be5b4ccaf92e94f4a0336b6c8c7bf779"},"headline":"Clean Room Requirements for Computer Hardware","datePublished":"2020-06-24T10:27:00+00:00","dateModified":"2025-10-29T15:18:14+00:00","mainEntityOfPage":{"@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/"},"wordCount":895,"image":{"@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage"},"thumbnailUrl":"","keywords":["Antimicrobial Computer","clean room","cleanroom","stainless steel computer"],"articleSection":["Technical Articles &amp; Industry Trends"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/","url":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/","name":"Clean Room Requirements for Computer Hardware | Teguar","isPartOf":{"@id":"https:\/\/teguar.com\/eu\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage"},"image":{"@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage"},"thumbnailUrl":"","datePublished":"2020-06-24T10:27:00+00:00","dateModified":"2025-10-29T15:18:14+00:00","author":{"@id":"https:\/\/teguar.com\/eu\/en\/#\/schema\/person\/be5b4ccaf92e94f4a0336b6c8c7bf779"},"description":"What is a cleanroom, how are clean rooms monitored, and what type of computers can be used for clean room manufacturing?","breadcrumb":{"@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/teguar.com\/eu\/en\/clean-room-computer-hardware\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/teguar.com\/eu\/en\/"},{"@type":"ListItem","position":2,"name":"Clean Room Requirements for Computer Hardware"}]},{"@type":"WebSite","@id":"https:\/\/teguar.com\/eu\/en\/#website","url":"https:\/\/teguar.com\/eu\/en\/","name":"Teguar","description":"Industrial PCs, Medical Computers, and Rugged Tablets","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/teguar.com\/eu\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/teguar.com\/eu\/en\/#\/schema\/person\/be5b4ccaf92e94f4a0336b6c8c7bf779","name":"Kathryn Armstrong","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c83b2b0424b6b6216f32b7790cb38c76d9ba87ccb83d2ff1f9fc00f916b0334c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c83b2b0424b6b6216f32b7790cb38c76d9ba87ccb83d2ff1f9fc00f916b0334c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c83b2b0424b6b6216f32b7790cb38c76d9ba87ccb83d2ff1f9fc00f916b0334c?s=96&d=mm&r=g","caption":"Kathryn Armstrong"},"url":"https:\/\/teguar.com\/eu\/en\/author\/kathryn-armstrong\/"}]}},"_links":{"self":[{"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/posts\/6897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/comments?post=6897"}],"version-history":[{"count":1,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/posts\/6897\/revisions"}],"predecessor-version":[{"id":2242434,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/posts\/6897\/revisions\/2242434"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/media?parent=6897"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/categories?post=6897"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/teguar.com\/eu\/en\/wp-json\/wp\/v2\/tags?post=6897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}